Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Sensing and quantification of gatifloxacin in real wastewater effluents using solid-contact ion-selective membranes

Sherif A Abdel-Gawad1,2 , Mubarak A Alamri1

1Department of Pharmaceutical Chemistry, College of Pharmacy, Prince Sattam Bin Abdulaziz University, Al Kharj 11942, Saudi Arabia; 2Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, ET-11562, Egypt.

For correspondence:-  Sherif Abdel-Gawad   Email: s.daif@psau.edu.sa   Tel:+966540586921

Accepted: 23 June 2023        Published: 31 July 2023

Citation: Abdel-Gawad SA, Alamri MA. Sensing and quantification of gatifloxacin in real wastewater effluents using solid-contact ion-selective membranes. Trop J Pharm Res 2023; 22(7):1435-1441 doi: 10.4314/tjpr.v22i7.11

© 2023 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To determine gatifloxacin hydrochloride (GTF) levels in real wastewater effluents.
Methods: In the last few years, the application of membrane-sensitive electrodes in the analysis of active pharmaceutical ingredients (APIs) has become a topic of paramount importance. Two ion-selective electrodes (ISEs) were fabricated using phosphotungstic acid (PTA) and sodium tetraphenylborate (TPB) as ion combining principles, for selective cum sensitive determination of gatifloxacin hydrochloride (GTF) in factory wastewater effluents. The membranes were successfully fabricated, and their performance was optimized. A validation scheme that followed IUPAC guidelines was implemented in the application of the sensors for sensitive determination of gatifloxacin hydrochloride.
Results: The fabricated membranes quantified the studied drug in a concentration range of 1 – 104 µM, with GTF-PTA and GTF-TPB electrodes showing gradients of 56.6 ± 0.40 and 57.8 ± 0.50 mV/decade, respectively. The fabricated sensors showed excellent working criteria in a pH range of one to five. A validation scheme was applied to the proposed method with respect to accuracy, robustness, and ruggedness. The suggested analytical procedure was effectively used for sensitive quantification of GTF in bulk form and in actual industrial water effluents.
Conclusion: The proposed method has been efficiently applied for the determination of GTF in wastewater samples without any sample pretreatment.

Keywords: Potentiometry, Gatifloxacin hydrochloride, Membrane-sensitive electrodes, Ion-pairing agents, Wastewater samples

Impact Factor
Thompson Reuters (ISI): 0.523 (2021)
H-5 index (Google Scholar): 39 (2021)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates